Mechanical Motor / Spring Wound Winding Single Pen Circular Chart Recorders

₹32,995.00

Compare

Your Gateway to Precision Control. Explore Our Online Store for Cutting-edge Instrumentation Solutions. Reliable Quality, Unparalleled Performance.

JI-CCR-MT-S mechanical single-pen circular chart recorder for industrial pressure and temperature recording.

Japsin Instrumentation – Since 1974

Description

JI-CCR-MT-S Mechanical Motor / Spring-Wound Single Pen Circular Chart Recorder

The “Ji” Japsin Instrumentation JI-CCR-MT-S Mechanical Motor / Spring-Wound Single Pen Circular Chart Recorder is designed for recording pressure or temperature variations over time in industrial monitoring, testing, and process documentation applications. Featuring a single-pen recording arrangement and a mechanical chart-drive system, this recorder provides a graphical record of changing process conditions that can be reviewed for analysis, inspection, and quality-control purposes.

Unlike a conventional pressure or temperature gauge that displays only the current measurement, a circular chart recorder creates a time-based record of changing values. This helps operators and engineers understand how a process behaves during a test or operating cycle, identify fluctuations, and maintain physical records for future reference.

The JI-CCR-MT-S is intended for applications using compatible Bourdon tube or gas-filled sensing arrangements, depending on the selected instrument configuration. Its mechanical motor or spring-wound drive provides chart movement without necessarily requiring an electronic chart-drive system. The exact drive arrangement and sensing configuration should be confirmed when selecting the model.

Mechanical Motor and Spring-Wound Chart Drive

The recorder uses a mechanical chart-drive arrangement intended to advance the circular chart over a defined recording period. In a spring-wound mechanism, stored mechanical energy drives the chart movement after the mechanism has been wound according to the manufacturer’s instructions.

This design can be useful in applications where a mechanically driven chart recorder is preferred. It also allows the recording process to be considered independently from the electrical requirements of electronic recording systems, although the complete instrument configuration should be checked for any additional power needs.

The chart rotation time, winding interval, and recording duration depend on the mechanism supplied. These details should be verified before purchase to ensure that the recorder meets the required monitoring period.

Single-Pen Circular Chart Recording

The JI-CCR-MT-S uses a single-pen configuration to record one measurement channel on a circular chart. As the measured pressure or temperature changes, the sensing mechanism moves the recording pen, producing a trace that represents the measurement over time.

This graphical record can help users review operating trends, observe fluctuations, and identify unusual changes during testing or production. A completed chart can also be retained as part of maintenance documentation, inspection records, or quality-control files.

The single-pen arrangement is particularly suitable when one process variable needs to be monitored and documented without the complexity of a multi-pen recording system.

Bourdon Tube Pressure Recording

For compatible pressure-measurement configurations, the recorder can use a Bourdon tube sensing mechanism. When pressure is applied to the curved elastic tube, it deforms slightly. The resulting mechanical movement is transferred through a linkage to operate the recording pen.

As pressure changes, the pen position changes accordingly, creating a graphical record on the circular chart. This makes the instrument useful for pressure testing, industrial process monitoring, and applications where a historical record of pressure behaviour is required.

The appropriate pressure range, process connection, and wetted materials must be selected according to the process conditions and the specific instrument configuration.

Gas-Filled Temperature Recording

The product description also identifies gas-filled operation for suitable configurations. Gas-filled temperature-measuring systems generally use a temperature-sensitive bulb connected to a pressure-responsive measuring mechanism through a capillary system.

As the bulb temperature changes, the sensing system responds and transfers movement to the recording mechanism. This can enable the instrument to record temperature variations over time, subject to the design and configuration of the supplied model.

The sensing system and chart recorder must be selected for the intended temperature range, installation arrangement, and environmental conditions. Confirm whether the required gas-filled temperature configuration is available for the exact JI-CCR-MT-S model.

Reliable Process Documentation

The circular chart format provides a physical record that can be reviewed after a measurement period. It can help users evaluate pressure or temperature trends, investigate process deviations, compare operating cycles, and maintain records for inspection.

Mechanical recording is useful in applications where a paper chart is preferred for documentation. For dependable results, the instrument should be installed correctly, operated within its specified limits, and maintained according to the manufacturer’s instructions.

Key Features

  • Model: JI-CCR-MT-S.
  • Mechanical motor / spring-wound circular chart-drive arrangement.
  • Single-pen recording configuration.
  • Circular chart for time-based measurement recording.
  • Bourdon tube pressure-measuring configuration, where specified.
  • Gas-filled temperature-measuring configuration, where specified.
  • Records one compatible process variable per recording channel.
  • Supports process trend review and physical recordkeeping.
  • Suitable for industrial monitoring, testing, and documentation.
  • Pressure or temperature range, accuracy, chart duration, and connection details to be confirmed for the selected configuration.

Applications

The JI-CCR-MT-S Mechanical Motor / Spring-Wound Single Pen Circular Chart Recorder may be suitable for:

  • Industrial pressure monitoring and recording.
  • Pressure testing equipment.
  • Process equipment monitoring.
  • Temperature recording in compatible gas-filled systems.
  • Industrial testing and inspection.
  • Machinery performance evaluation.
  • Maintenance and troubleshooting.
  • Quality-control and process documentation.
  • Applications requiring a physical record of pressure or temperature changes.

Installation and Operating Considerations

Before ordering, confirm whether the intended application requires pressure recording through a Bourdon tube or temperature recording through a gas-filled sensing system. Verify the measurement range, connection arrangement, sensing element, chart dimensions, and recording duration for the selected configuration.

For spring-wound versions, follow the manufacturer’s instructions for winding and chart replacement. For pressure applications, ensure that the complete sensing assembly and connections are rated for the operating conditions. For temperature applications, confirm the suitability of the bulb, capillary, and measuring system for the installation environment.

Calibration and maintenance should follow the manufacturer’s recommendations, especially where recorded data is used for quality-control or process verification.

Product Summary

The JI-CCR-MT-S Mechanical Motor / Spring-Wound Single Pen Circular Chart Recorder is designed for applications requiring a graphical record of pressure or temperature changes over time. Its single-pen circular chart format and mechanical drive arrangement provide a practical option for industrial monitoring, testing, and process documentation.

With Bourdon tube and gas-filled sensing configurations identified for the product range, the recorder can be considered for compatible pressure or temperature applications. Confirm the required sensing arrangement, measurement range, accuracy, chart rotation period, and connection details before ordering to ensure the supplied instrument meets the intended application requirements.

Japsin Instrumentation – Since 1974

Additional information

Make:

"Ji" Japsin Instrumentation

Model

JI-CP-MINI-100

Range

0 to 100 Kg/Cm2

Certificate

Calibration Certificate Traceable To NPL Provided

Gauge

Not Included

Warranty

1 year for any manufacturing defects

Reviews

There are no reviews yet.

Be the first to review “Mechanical Motor / Spring Wound Winding Single Pen Circular Chart Recorders”