Comparison Vacuum Calibrator Range -710 mmHg
High Precision Vacuum Comparison Test Pump for Vacuum Gauge Calibration and Verification
The RAVIKA Comparison Vacuum Calibrator Range -710 mmHg is a precision-engineered vacuum generation and calibration system designed for accurate testing, verification, and calibration of vacuum gauges, compound gauges, vacuum transmitters, vacuum switches, pressure-vacuum instruments, and other vacuum measuring devices. Utilizing the widely accepted comparison calibration method, this vacuum calibrator enables technicians and calibration professionals to compare the readings of a vacuum instrument under test against a calibrated master vacuum gauge under identical vacuum conditions.
Built for industrial calibration laboratories, maintenance departments, manufacturing plants, pharmaceutical facilities, research laboratories, HVAC industries, and process industries, the RAVIKA Comparison Vacuum Calibrator provides a simple, reliable, and cost-effective solution for routine vacuum instrument calibration.
The unit is capable of generating vacuum up to -710 mmHg, making it suitable for a wide range of industrial vacuum calibration applications. The calibrator is equipped with a precision screw pump, dual gauge mounting stations, vacuum isolation system, atmospheric release valve, and a sturdy base plate for stable operation. A complete accessory package is supplied including adaptors, spare seals, spanners, dust cover, and instruction manual. The master gauge is not included, allowing users to select a certified reference gauge suitable for their specific calibration requirements.
What is a Comparison Vacuum Calibrator?
A comparison vacuum calibrator is a vacuum generation device used to calibrate vacuum instruments by comparing their readings with a calibrated reference instrument known as a master gauge.
In the comparison method, both the master vacuum gauge and the instrument under test are connected to the same vacuum source. The vacuum generated within the circuit is applied equally to both instruments. The readings are then compared at various calibration points to determine the accuracy of the instrument being tested.
This method is one of the most practical and economical calibration techniques used in industrial maintenance and laboratory environments.
Working Principle
The RAVIKA Comparison Vacuum Calibrator operates using a manually controlled screw pump mechanism designed to generate vacuum within a closed calibration circuit.
The master gauge and the vacuum instrument under test are mounted on the two gauge connectors provided on the calibrator. As the screw pump is operated, vacuum is gradually generated within the system. Since both instruments are connected to the same circuit, they experience identical vacuum conditions.
The operator compares the readings displayed by both instruments and identifies any deviations. Calibration adjustments can then be made if required.
The system also includes an atmospheric release valve that allows the vacuum circuit to be connected directly to the atmosphere for quick zero verification of the gauges before calibration begins.
Vacuum Generation up to -710 mmHg
The calibrator is capable of generating vacuum up to -710 mmHg, covering the majority of industrial vacuum measurement applications.
This vacuum range is suitable for calibration of:
- Vacuum Gauges
- Compound Gauges
- Vacuum Transmitters
- Vacuum Switches
- Digital Vacuum Indicators
- Pressure-Vacuum Instruments
- Vacuum Sensors
- Laboratory Vacuum Instruments
- Process Vacuum Monitoring Devices
The wide operating range makes the calibrator highly versatile and suitable for both workshop and laboratory environments.
Precision Screw Pump for Accurate Vacuum Generation
At the heart of the system is a precision-engineered screw pump designed specifically for controlled vacuum generation.
Benefits of the Screw Pump
- Smooth vacuum generation
- Fine vacuum adjustment
- Stable vacuum conditions
- Accurate calibration point setting
- Easy operation
- High repeatability
The screw pump enables technicians to generate vacuum gradually and precisely, eliminating sudden pressure fluctuations that could affect calibration accuracy.
This level of control is particularly important when calibrating sensitive vacuum instruments.
Dual Gauge Connection Arrangement
The RAVIKA Comparison Vacuum Calibrator is equipped with two dedicated gauge connectors fitted with ½” BSP connections.
Configuration
- One connector for the Master Vacuum Gauge
- One connector for the Instrument Under Test
Both instruments are exposed to the same vacuum source, allowing direct and accurate comparison of readings.
Advantages
- Simultaneous calibration
- Faster testing process
- Improved accuracy
- Reduced setup time
- Easy instrument mounting
The dual connector arrangement makes the calibration process simple and highly efficient.
Atmospheric Release Valve for Zero Verification
A special valve is incorporated into the vacuum circuit that allows connection to atmospheric pressure.
Purpose of the Valve
- Quick zero checking
- Verification before calibration
- Easy vacuum release
- Safe operation
- Faster testing cycle
Before starting calibration, operators can connect the system to atmosphere and verify that both gauges return to zero correctly. This ensures confidence in the calibration results and helps identify any instrument issues before testing begins.
Sturdy Industrial Base Plate
The entire calibrator assembly is mounted on a heavy-duty base plate with supporting legs.
Benefits
- Stable operation
- Reduced vibration
- Better handling
- Improved portability
- Enhanced durability
The sturdy construction makes the calibrator suitable for continuous industrial use and field service applications.
Importance of Vacuum Calibration
Vacuum measurement plays a critical role in numerous industrial processes.
Inaccurate vacuum readings can result in:
- Product quality issues
- Process instability
- Reduced equipment efficiency
- Energy losses
- Safety concerns
- Increased maintenance costs
Routine vacuum calibration helps maintain:
- Measurement accuracy
- Process reliability
- Product consistency
- Equipment performance
- Compliance with quality standards
The RAVIKA Comparison Vacuum Calibrator provides a dependable method for maintaining vacuum instrument accuracy.
Standard Accessories Supplied
The calibrator is supplied with a complete accessory package including:
- Comparison Vacuum Calibrator
- Precision Screw Pump
- Two Gauge Mounting Stations
- ½” BSP Gauge Connectors
- Dust Cover
- Instruction Manual
- Tool Kit
- M20 x 1.5 Adaptor
- ¼” BSP Adaptor
- ⅜” BSP Adaptor
- Spare Seal Kit
- Three Service Spanners
These accessories allow connection of various vacuum instruments commonly used across industries.
Master Gauge Not Included
The RAVIKA Comparison Vacuum Calibrator is supplied without a master gauge.
This allows users to select a certified master gauge according to their required calibration accuracy and quality standards.
For traceable calibration, the master gauge should be periodically verified against a certified Dead Weight Vacuum Gauge Tester.
Why Choose RAVIKA Comparison Vacuum Calibrator?
The RAVIKA Comparison Vacuum Calibrator offers an economical, reliable, and highly accurate solution for vacuum instrument calibration. Its precision screw pump, dual gauge connection system, atmospheric release valve, rugged construction, and complete accessory package make it an ideal choice for calibration laboratories, maintenance departments, service organizations, and industrial facilities.
Designed for quick and accurate vacuum calibration, the unit provides stable vacuum generation, simple operation, and long-term durability. Whether used for routine maintenance, laboratory calibration, quality assurance programs, or process verification, the RAVIKA Comparison Vacuum Calibrator Range -710 mmHg delivers dependable performance and professional calibration results.
For organizations seeking a practical and efficient vacuum calibration solution, the RAVIKA Comparison Vacuum Calibrator is a valuable tool that ensures measurement accuracy, process reliability, and long-term operational confidence.
Japsin Instrumentation – Since 1974

Reviews