Auto Digital Conductivity Temp. Meter – JIPL-467 | Automatic Temperature Compensation Conductivity Meter

₹9,000.00

Available on back-order

Compare
SKU: JIPL-467 Category:

Your Gateway to Precision Control. Explore Our Online Store for Cutting-edge Instrumentation Solutions. Reliable Quality, Unparalleled Performance.

Auto Digital Conductivity Meter JIPL-467 with automatic temperature compensation, multiple ppm and ppt ranges, platinum DIP-type cell and LED display.

Japsin Instrumentation – Since 1974

Description

Auto Digital Conductivity Temp. Meter – JIPL-467 | Automatic Temperature Compensation Conductivity Meter

An Auto Digital Conductivity Temp. Meter is an advanced electronic measuring instrument designed to measure the electrical conductivity and temperature-related characteristics of liquid samples. It is widely used in water treatment plants, pharmaceutical industries, chemical processing facilities, food and beverage industries, research laboratories, educational institutions, and industrial quality control departments where accurate conductivity measurement is essential.

The JIPL Auto Digital Conductivity Temp. Meter – JIPL-467 is designed to provide reliable, stable, and accurate conductivity measurements with automatic range selection and automatic temperature compensation (ATC). It incorporates advanced electronic measurement technology, an adjustable cell constant facility, and a platinum DIP-type conductivity cell to support routine laboratory and industrial testing requirements.

The instrument features multiple measurement ranges covering 0–200 ppm, 0–2000 ppm, 0–20 ppt, 0–200 ppt, and 0–1000 ppt. Its automatic range selection facility provides flexibility when testing liquid samples with different dissolved ionic concentrations.

Automatic Temperature Compensation (ATC)

Temperature is an important factor affecting electrical conductivity measurements. As the temperature of a liquid changes, the mobility of dissolved ions also changes, which can influence the conductivity reading.

The JIPL-467 features an automatic temperature compensation facility that helps adjust conductivity measurements according to the detected sample temperature. This functionality improves measurement consistency when testing samples under varying temperature conditions.

The instrument also supports manual temperature compensation within the specified range of 0–50°C, providing flexibility for different testing environments and operating requirements.

Automatic Range Selection for Convenient Measurement

The JIPL Auto Digital Conductivity Temp. Meter offers multiple measurement ranges to accommodate different sample concentrations.

Its automatic range selection facility supports the following ranges:

  • 0–200 ppm
  • 0–2000 ppm
  • 0–20 ppt
  • 0–200 ppt
  • 0–1000 ppt

This facility allows users to measure samples across different concentration levels without manually changing the measurement range for every sample. It is particularly useful in laboratories and industrial environments where samples with varying dissolved ionic content are tested regularly.

Adjustable Cell Constant Facility

The conductivity cell plays an important role in determining the accuracy of conductivity measurements. The cell constant establishes the relationship between the measured electrical conductance and the actual conductivity of a solution.

The JIPL-467 features an adjustable cell constant facility, allowing users to configure the instrument according to the conductivity cell being used. This supports measurement flexibility across different sample types and conductivity levels.

The instrument is supplied with a platinum DIP-type conductivity cell designed for immersion-based liquid measurement. Proper cell calibration, cleaning, and maintenance help maintain reliable and repeatable measurement performance.

High Resolution and Measurement Accuracy

The JIPL-467 is designed to provide dependable measurement performance for routine laboratory and industrial testing. It features a specified resolution of 0.1 µS and an accuracy of ±1% FS ±1 digit.

These measurement characteristics support consistent conductivity monitoring and quality control activities. The instrument is suitable for applications where monitoring dissolved ionic content and changes in liquid conductivity is important.

Clear 3½-Digit LED Display

The instrument is equipped with a 3½-digit LED display that provides clear numerical measurement readings. The digital display allows operators to observe and record measurement values conveniently during testing.

Its simple operating arrangement makes it suitable for laboratory technicians, researchers, quality control professionals, and industrial operators.

The automatic range selection and temperature compensation facilities further simplify routine conductivity testing and help improve operational convenience.

Durable Metal Body Construction

The JIPL Auto Digital Conductivity Temp. Meter features a durable metal body designed for regular laboratory and industrial use.

With compact dimensions of 220 × 190 × 100 mm and an approximate weight of 2 kg, the instrument can be conveniently positioned on laboratory workbenches and testing stations.

It operates on a 230V ±10% AC, 50Hz power supply, making it suitable for standard laboratory electrical installations.

Wide Range of Industrial and Laboratory Applications

The JIPL-467 Auto Digital Conductivity Temp. Meter is suitable for different industries where monitoring the conductivity of liquid samples is essential.

Common applications include:

  1. Water Treatment Plants: Monitoring dissolved ionic content during water purification, filtration, and treatment processes.
  2. Pharmaceutical Industries: Checking purified water and process water quality during manufacturing and quality control.
  3. Chemical Processing Industries: Monitoring conductivity changes in chemical solutions and industrial liquids.
  4. Food and Beverage Industries: Testing process water, liquid ingredients, and production water quality.
  5. Educational and Research Laboratories: Conducting conductivity experiments, chemical analysis, and scientific research.
  6. Boiler and Cooling Water Systems: Monitoring conductivity to support water quality management.
  7. Environmental Testing: Analysing water samples and monitoring changes in dissolved ionic concentrations.
  8. Agriculture and Hydroponics: Testing irrigation water and nutrient solutions.

Standard Accessories

The JIPL-467 Auto Digital Conductivity Temp. Meter is supplied with essential accessories to support installation and routine measurement activities.

Standard accessories include:

  • Conductivity Cell
  • Operation Manual
  • Dust Cover
  • Temperature Probe
  • Conductivity Cell Stand

These accessories help users perform conductivity measurements and monitor sample temperature conveniently.

Why Choose the JIPL Auto Digital Conductivity Temp. Meter?

  • Automatic temperature compensation facility.
  • Automatic measurement range selection.
  • Multiple measurement ranges from ppm to ppt.
  • Measurement accuracy of ±1% FS ±1 digit.
  • Specified resolution of 0.1 µS.
  • Adjustable cell constant facility.
  • Platinum DIP-type conductivity cell.
  • Clear 3½-digit LED display.
  • Manual and automatic temperature compensation options.
  • Durable metal body construction.
  • Compact table-top design.
  • Suitable for laboratory, industrial, and water quality testing applications.

Conclusion

The JIPL Auto Digital Conductivity Temp. Meter – JIPL-467 is a practical and reliable instrument for monitoring electrical conductivity and dissolved ionic content in liquid samples. Its automatic temperature compensation, automatic range selection, adjustable cell constant, and platinum DIP-type conductivity cell make it suitable for different laboratory and industrial testing requirements.

Whether used in water treatment plants, pharmaceutical laboratories, chemical processing facilities, food manufacturing units, or research centres, the JIPL-467 provides a convenient solution for routine conductivity measurement and water quality monitoring.

Japsin Instrumentation – Since 1974

Additional information

Brand

"Ji" Japsin Instrumentation

Product Name

Auto Digital Conductivity Temp. Meter

Model Number

JIPL-467

Instrument Type

Table-Top Digital Conductivity Meter

Display

3½-Digit LED

Measurement Range

0–200 ppm, 0–2000 ppm, 0–20 ppt, 0–200 ppt, 0–1000 ppt

Range Selection

Automatic

Temperature Compensation

Automatic (ATC) / Manual

Manual Temperature Compensation Range

0–50°C

Cell Constant

Adjustable

Conductivity Cell

Platinum DIP Type

Resolution

0.1 µS

Accuracy

±1% FS ±1 Digit

Body Material

Metal Body

Power Supply

230V ±10% AC, 50 Hz

Dimensions

220 × 190 × 100 mm

Weight

Approx. 2 kg

Reviews

There are no reviews yet.

Be the first to review “Auto Digital Conductivity Temp. Meter – JIPL-467 | Automatic Temperature Compensation Conductivity Meter”