Description
Digital Disintegration Test Apparatus
The Digital Disintegration Test Apparatus by Japsin Instrumentation is designed for evaluating the disintegration time of pharmaceutical tablets and capsules. It is an essential testing instrument for pharmaceutical manufacturing units, quality-control laboratories, research facilities and educational institutions involved in dosage-form testing.
Disintegration testing is an important part of pharmaceutical quality control. It helps determine the time required for a tablet or capsule to break down into smaller particles under specified testing conditions. This test provides useful information about the physical breakdown behaviour of solid dosage forms and helps manufacturers evaluate product consistency during development and routine production.
The apparatus is designed with a digitally programmable timer, controlled up-and-down basket movement and a hot-plate heating arrangement. These features support a controlled testing process and allow laboratory personnel to monitor the duration of the disintegration test.
Working Principle
The Digital Disintegration Test Apparatus operates by moving a basket assembly containing the test dosage forms vertically in a liquid medium maintained under the specified testing conditions. During the test, the basket assembly repeatedly moves up and down at a controlled speed.
The tablets or capsules are placed in the designated positions within the basket assembly. The basket is then operated in the selected liquid medium, and the movement allows the samples to experience repeated immersion and withdrawal during the testing cycle.
The instrument maintains a specified movement frequency and stroke length. The time required for the dosage form to disintegrate is monitored using the digital timer. The test is performed according to the applicable pharmacopoeial procedure and the requirements of the product being evaluated.
Digital Programmable Timer
The apparatus features a digital programmable timer that allows users to set the required testing duration. The timer can be programmed from 1 second up to 99 hours, 59 minutes and 59 seconds.
The digital time display helps laboratory personnel monitor the progress of the test without relying on a separate manual stopwatch. Once the programmed time is completed, the apparatus automatically stops and provides an audible alarm.
This automatic stopping and alarm facility helps notify the operator when the programmed test cycle has finished. It is particularly useful in laboratories conducting repeated testing activities or handling multiple samples.
Controlled Basket Movement
Consistent basket movement is an important factor in disintegration testing. The apparatus is designed with a low-RPM AC motor that drives the basket assembly through a controlled vertical movement.
Both available models operate at an up-and-down speed of 30 ± 2 strokes per minute, with an up-and-down movement length of 55 ± 5 mm.
These specified operating parameters support repeatable mechanical movement during testing. The basket assembly moves through the selected liquid medium, allowing the samples to undergo the prescribed immersion and withdrawal cycle.
Hot-Plate Heating Arrangement
The Digital Disintegration Test Apparatus uses a hot-plate heating arrangement for maintaining the testing medium at the required temperature. A separate regulator is provided for controlling the heating operation.
Maintaining the appropriate temperature of the test medium is important because temperature can influence the disintegration behaviour of tablets and capsules. The separate heating regulator allows the operator to adjust the heating process according to the applicable test method.
The actual testing temperature should be selected and monitored in accordance with the relevant pharmacopoeial requirements and the procedure specified for the dosage form.
Hold and Resume Facility
The apparatus includes a hold-and-resume facility that allows the operator to temporarily pause an ongoing test for sample inspection. After inspection, the test can be resumed as required.
This function is useful when the operator needs to observe the condition of the samples during the test. It provides additional control over the testing sequence without requiring the entire procedure to be restarted.
The facility is available on both JIPL-273 and JIPL-274 configurations.
Power Failure Protection
The instrument includes memory protection for preserving the running test in the event of a power failure. This feature is designed to protect the status of an ongoing test and reduce the need for unnecessary re-entry of test settings after a power interruption.
The power-failure memory feature is particularly relevant for laboratory environments where maintaining the continuity of testing operations is important. The exact recovery behaviour and retention duration should be confirmed with the supplier.
Single and Double Basket Configurations
The Digital Disintegration Test Apparatus is available in two configurations to suit different laboratory testing requirements.
JIPL-273 – Single Basket Model
The JIPL-273 is equipped with a single basket configuration. It is suitable for laboratories that require a single-basket arrangement for routine tablet and capsule disintegration testing. It includes a digital programmable timer, hot-plate heating, low-RPM AC motor, audible alarm and hold-and-resume facility.
JIPL-274 – Double Basket Model
The JIPL-274 features a double basket configuration. It is designed for laboratories that require a two-basket arrangement for their testing workflow. It includes the same specified movement speed, stroke length, digital timer range, heating arrangement and operating facilities as the JIPL-273 model.
The selection between the single-basket and double-basket models depends on laboratory workflow, sample-testing requirements and the applicable testing procedure.
Applications of Digital Disintegration Test Apparatus
The instrument is suitable for disintegration testing applications in different pharmaceutical and laboratory environments, including:
- Pharmaceutical manufacturing: Routine disintegration testing of tablets and capsules during production quality control.
- Quality-control laboratories: Evaluation of dosage-form disintegration time against established test procedures.
- Research and development laboratories: Assessment of tablet and capsule formulations during product development.
- Pharmaceutical testing institutions: Laboratory testing of solid oral dosage forms.
- Educational institutions: Demonstration and study of pharmaceutical disintegration testing principles.
- Contract testing laboratories: Disintegration testing services for suitable pharmaceutical samples.
Why Choose Japsin Instrumentation Digital Disintegration Test Apparatus?
The Digital Disintegration Test Apparatus offers a combination of programmable time control, controlled basket movement, hot-plate heating and operator-oriented testing functions. Its automatic stopping and audible alarm help monitor test completion, while the hold-and-resume facility supports sample inspection during an ongoing test.
With single-basket and double-basket configurations available, laboratories can select the arrangement that best suits their testing requirements.
The apparatus is intended for pharmaceutical quality-control applications where monitoring the disintegration behaviour of tablets and capsules is an important part of product evaluation. Its specified operating parameters and digital timer provide a structured platform for conducting routine disintegration tests.
Japsin Instrumentation offers laboratory testing and measurement equipment for pharmaceutical, industrial and research applications.
Key Features
-
Available in single-basket and double-basket configurations.
-
Digital programmable timer with a range up to 99 hours, 59 minutes and 59 seconds.
-
Automatic stop after completion of the programmed time.
-
Audible alarm for test completion.
-
Memory protection for running tests during power failure.
-
Separate regulator for heating control.
-
Hold-and-resume facility for sample inspection.
-
Controlled basket movement at 30 ± 2 strokes per minute.
-
Up-and-down movement length of 55 ± 5 mm.
-
Low-RPM AC motor.
-
Hot-plate heating arrangement.