Description
Digital Dissolved Oxygen Indicator Online
The JIPL Digital Dissolved Oxygen Indicator Online is an electronic measurement instrument designed for monitoring dissolved oxygen (DO) concentration in water and other suitable liquid samples. Developed for online measurement applications, this instrument helps operators monitor oxygen levels in water systems and maintain awareness of changing water-quality conditions.
Dissolved oxygen is an important parameter in water treatment, wastewater management, aquaculture, environmental monitoring and several industrial processes. The amount of oxygen present in water can influence biological activity, treatment efficiency and the overall condition of aquatic environments. Continuous dissolved oxygen monitoring helps operators identify changes in oxygen concentration and take appropriate corrective action when required.
The JIPL Digital Online DO Indicator features a measurement range of 0 to 20 ppm, a resolution of 0.01 ppm and automatic temperature compensation (ATC). It uses an amperometric gold/silver membrane-type dissolved oxygen sensor and a 3½-digit LED display for presenting measurement readings.
Its compact panel-mount construction, temperature compensation facility and digital display make it suitable for installations where dissolved oxygen readings need to be monitored as part of regular process or water-quality management.
Online Dissolved Oxygen Monitoring
The instrument is designed for dissolved oxygen monitoring in applications where operators need to observe oxygen concentration without relying exclusively on occasional manual testing.
Dissolved oxygen measurement is particularly important in water and wastewater treatment systems, where oxygen availability can influence biological treatment processes. It is also relevant to aquaculture, where maintaining suitable oxygen levels is important for aquatic organisms.
The JIPL Online DO Indicator measures dissolved oxygen over a specified range of 0–20 ppm. Its 0.01 ppm resolution allows the display to show small changes in the measured value. The manufacturer specifies an accuracy of 0.01 ppm; this figure should be confirmed with the supplier before being treated as a guaranteed accuracy specification.
Amperometric Gold/Silver Membrane-Type Sensor
The instrument uses an amperometric gold/silver membrane-type dissolved oxygen sensor. This sensing technology measures oxygen through an electrochemical process involving electrodes and a selective membrane.
Oxygen passes through the membrane and participates in the electrochemical reaction at the sensing electrodes. The resulting electrical signal is related to the dissolved oxygen concentration and is processed by the indicator to provide a digital reading.
The membrane plays an important role in sensor performance. Proper membrane installation, suitable electrolyte or sensor preparation where applicable, and regular inspection are important for maintaining reliable operation.
The manufacturer lists a DO probe and a set of DO membranes among the standard accessories. Users should follow the supplied instructions for sensor preparation, maintenance and membrane replacement.
Automatic Temperature Compensation
Temperature affects dissolved oxygen solubility in water. As water temperature changes, the amount of oxygen that can remain dissolved under equilibrium conditions also changes. Temperature compensation is therefore an important feature in dissolved oxygen measurement.
The JIPL Digital Online DO Indicator includes automatic temperature compensation (ATC) and supports a temperature range of 0–55°C. The specified temperature resolution is 0.1°C, with stated temperature accuracy of 0.1°C.
ATC helps the instrument account for temperature variations during measurement. This is useful in water treatment and industrial applications where sample temperature may change during operation.
For dependable results, the temperature sensor must be correctly installed and positioned according to the manufacturer’s instructions. Confirm the supplied sensor configuration and installation arrangement before commissioning the instrument.
Digital LED Display
The instrument features a 3½-digit LED display for presenting dissolved oxygen readings. Its digital display allows operators to monitor measurement values conveniently during routine operation.
The display arrangement is suitable for panel-mounted applications where operators need to observe dissolved oxygen values as part of a process monitoring system. The compact front-panel dimensions of 96 × 96 mm make the instrument suitable for compatible panel installations.
Manual Calibration Facility
The JIPL Digital Dissolved Oxygen Indicator provides manual calibration. Calibration is essential for maintaining measurement reliability and should be performed according to the manufacturer’s recommended procedure.
Regular calibration helps establish the correct measurement reference and supports consistent readings over time. Calibration frequency may depend on the sample conditions, operating environment, sensor condition and application requirements.
The DO probe and membrane should also be inspected periodically. Damaged membranes, improper sensor preparation or contamination can affect measurement performance.
Compact Panel-Mount Construction
The instrument is designed in a compact panel-mount format with front dimensions of 96 × 96 mm. Its approximate weight is 600 g, making it suitable for installation in compatible control panels and monitoring enclosures.
The instrument operates on a 230 V AC ±10%, 50 Hz power supply. Its compact design makes it practical for installations where available panel space is limited.
For online applications, the probe installation, cable routing, process connection and mounting arrangement should be checked against the actual supplied configuration. The manufacturer page does not publish a detailed probe mounting or process connection specification, so these details should be confirmed before installation planning.
Applications Across Multiple Industries
The JIPL Digital Dissolved Oxygen Indicator Online can be used in suitable applications involving water-quality monitoring and dissolved oxygen measurement, including:
- Water treatment plants: Monitoring dissolved oxygen levels in water treatment systems.
- Wastewater treatment plants: Observing oxygen concentration in biological treatment processes.
- Aquaculture and fish farming: Monitoring dissolved oxygen conditions in suitable fish tanks and water systems.
- Environmental monitoring: Supporting dissolved oxygen measurement in water-quality monitoring applications.
- Industrial water systems: Monitoring oxygen levels in suitable process-water applications.
- Research laboratories: Supporting continuous or installation-based dissolved oxygen monitoring.
- Chemical and biological industries: Monitoring dissolved oxygen where oxygen concentration is an important process parameter.
- Water quality management: Helping operators identify changes in dissolved oxygen concentration.
Standard Accessories
The manufacturer lists a dissolved oxygen probe, a set of DO membranes, NO₂ and SO₃ powder solution (one set), and an operation manual as standard accessories.
The exact sensor installation arrangement, temperature-sensing provision and purpose of the supplied powder solutions should be confirmed with the supplier before commissioning.
A Practical Solution for Online DO Monitoring
The JIPL Digital Dissolved Oxygen Indicator Online combines a 0–20 ppm dissolved oxygen measurement range, 0.01 ppm resolution, amperometric gold/silver membrane-type sensor and automatic temperature compensation in a compact 96 × 96 mm panel-mount instrument.
Its LED display and temperature compensation facility make it suitable for applications where operators need convenient dissolved oxygen monitoring in water and industrial process systems.
For reliable operation, the instrument should be installed with a compatible DO probe, calibrated according to the recommended procedure and maintained through regular membrane and sensor inspection. Before ordering, users should confirm the probe mounting arrangement, cable length, temperature sensor configuration and any required process installation accessories.
Standard accessories
-
DO probe – 1 No.
-
Set of DO membranes
-
NO₂ and SO₃ powder solution – 1 set
-
Operation manual – 1 No.
Japsin Instrumentation – Since 1974

Reviews
There are no reviews yet.