Explore the JIPL Digital DO Cum Temperature Meter with 0–20 ppm dissolved oxygen range, 0.01 ppm resolution, membrane-type DO probe and manual temperature compensation.

Japsin Instrumentation – Since 1974

Description

Digital DO Cum Temperature Dissolved Oxygen Meter

The JIPL Digital DO Cum Temperature Dissolved Oxygen Meter is a laboratory instrument designed for measuring dissolved oxygen concentration and monitoring temperature in water and other suitable liquid samples. It combines digital dissolved oxygen measurement with temperature-related functions, making it useful for water quality testing, environmental monitoring, wastewater treatment, aquaculture, research laboratories and industrial applications.

Dissolved oxygen (DO) is an important parameter for evaluating water quality and understanding the oxygen available in aquatic environments. It plays a significant role in biological activity, wastewater treatment processes, fish farming, environmental studies and industrial water management. Regular dissolved oxygen monitoring helps laboratory personnel and process operators assess water conditions and maintain suitable operating parameters.

The JIPL Digital DO Cum Temperature Meter is available in two configurations, based on the manufacturer’s JIPL-469 and JIPL-470 models. Both versions offer a dissolved oxygen measurement range of 0 to 20 ppm, with a resolution of 0.01 ppm. The JIPL-469 version additionally includes a Pt100 temperature sensor and temperature display facility.

Dissolved Oxygen Measurement

The instrument is designed to measure dissolved oxygen concentration over a range of 0–20 ppm. Dissolved oxygen readings help users evaluate the oxygen content of water samples and monitor changes under different environmental and operating conditions.

The specified DO resolution is 0.01 ppm, allowing the instrument to display small changes in dissolved oxygen readings. The manufacturer lists DO accuracy as 0.01 ppm for both models. This specification should be confirmed with the supplier before publication as a guaranteed accuracy value.

The instrument uses an amperometric gold/silver membrane-type DO probe. This type of sensor measures oxygen through an electrochemical sensing arrangement involving a membrane and electrode system. The membrane separates the sensing components from the sample while allowing oxygen to reach the sensing element.

Correct probe preparation, membrane condition, calibration and maintenance are important for dependable dissolved oxygen measurements.

Gold/Silver Membrane-Type DO Sensor

The JIPL Digital DO Meter is supplied with an amperometric gold/silver membrane-type dissolved oxygen probe. The sensing arrangement is designed for measuring oxygen concentration in liquid samples.

The membrane plays an important role in the operation of the probe by allowing oxygen to pass into the sensor while separating the electrode system from the sample. Proper membrane installation and maintenance help support consistent sensor performance.

The manufacturer lists a set of DO membranes and powder solution among the accessories. Users should follow the recommended probe preparation, membrane replacement and maintenance instructions supplied with the instrument.

Temperature Measurement and Compensation

Temperature is an important factor in dissolved oxygen testing because oxygen solubility in water changes with temperature. The JIPL Digital DO Cum Temperature Meter provides temperature-related functions to help users account for sample temperature during dissolved oxygen measurement.

Both models specify a temperature range of 0 to 55°C, temperature resolution of 0.1°C and temperature accuracy of 0.1°C. Manual temperature compensation is provided, allowing the operator to enter the applicable temperature value according to the sample conditions.

The JIPL-469 model includes a Pt100 temperature sensor and a temperature display range of 0 to 100°C. The JIPL-470 specification does not list a temperature sensor or temperature display range. Therefore, users who require direct temperature measurement should select the appropriate model after confirming its configuration.

Manual Calibration Facility

The instrument provides manual calibration for dissolved oxygen measurement. Calibration is an important step in maintaining measurement reliability and should be carried out according to the recommended operating procedure.

Proper calibration helps establish the measurement reference before testing samples. Users should also ensure that the DO probe is correctly prepared, the membrane is in good condition and the sample is handled appropriately.

Regular inspection of the sensor and replacement of membranes when required are recommended to maintain consistent operation.

Digital LED Display

The instrument features a 3½-digit LED display for presenting measurement readings. Its digital display allows users to observe dissolved oxygen values during routine laboratory testing and water quality monitoring.

The straightforward display arrangement makes the instrument suitable for laboratories, educational institutions and industrial testing environments where convenient reading of measurement values is required.

Compact Tabletop Design

The JIPL Digital DO Cum Temperature Meter has a compact tabletop design with published dimensions of 275 × 175 × 76 mm and an approximate weight of 2 kg. Its compact construction makes it convenient to position on laboratory workbenches and testing counters.

The instrument operates on a 230 V AC ±10%, 50 Hz power supply. The supplied dust cover helps protect the instrument when it is not in use.

Applications Across Multiple Industries

The JIPL Digital DO Cum Temperature Dissolved Oxygen Meter can support dissolved oxygen testing in various applications, including:

  • Water quality laboratories: Monitoring dissolved oxygen levels in suitable water samples.
  • Wastewater treatment plants: Checking oxygen levels during wastewater treatment and related testing procedures.
  • Aquaculture and fisheries: Monitoring dissolved oxygen in fish ponds, tanks and aquaculture systems.
  • Environmental monitoring: Supporting water quality assessment and environmental testing.
  • Research laboratories: Measuring dissolved oxygen during experiments and laboratory investigations.
  • Educational institutions: Demonstrating dissolved oxygen measurement and water quality testing principles.
  • Industrial water management: Monitoring oxygen concentration in suitable industrial water applications.
  • Chemical and biological laboratories: Supporting testing procedures where dissolved oxygen is an important parameter.

Standard Accessories

The manufacturer’s published accessory list includes a dissolved oxygen probe, a set of DO membranes, NO₂ and SO₃ powder solutions, a temperature sensor for the JIPL-469 configuration, a dust cover and an operation manual.

The exact accessory configuration should be checked before ordering, particularly for the temperature sensor and supplied powder solutions. The manufacturer’s accessory list does not explain the intended use or preparation procedure for the NO₂ and SO₃ solutions, so users should refer to the supplied manual.

Two Model Options for Different Testing Requirements

The JIPL Digital DO Cum Temperature Dissolved Oxygen Meter is offered in two configurations based on the manufacturer’s published models:

JIPL-469 configuration: Includes a Pt100 temperature sensor and temperature display facility, in addition to dissolved oxygen measurement and manual temperature compensation.

JIPL-470 configuration: Provides dissolved oxygen measurement and manual temperature compensation, but the published specifications do not list a Pt100 sensor or temperature display range.

This distinction helps users select the instrument according to whether direct temperature sensing and display are required.

A Practical Instrument for Dissolved Oxygen Testing

The JIPL Digital DO Cum Temperature Dissolved Oxygen Meter combines a 0–20 ppm dissolved oxygen measurement range, 0.01 ppm resolution, amperometric gold/silver membrane-type sensor and manual calibration in a compact tabletop instrument.

With two available configurations, digital LED display and temperature-related functions, it is a practical choice for laboratories and industries involved in water quality testing, environmental monitoring and dissolved oxygen analysis.

For dependable measurements, users should select the appropriate model, maintain the DO probe and membrane, follow the recommended calibration procedure and verify temperature compensation settings. The final probe and accessory configuration should be confirmed before ordering.

Standard accessories

  • DO probe – 1 No.

  • Set of DO membranes

  • NO₂ powder solution

  • SO₃ powder solution

  • Temperature sensor – listed for JIPL-469

  • Dust cover – 1 No.

  • Operation manual – 1 No.

Japsin Instrumentation – Since 1974

Additional information

Brand

"Ji" Japsin Instrumentation

Product name

Digital DO Cum Temperature Dissolved Oxygen Meter

Models

JIPL-469

Measurement parameter

Dissolved Oxygen (DO)

DO measurement range

0–20 ppm

DO resolution

0.01 ppm

DO accuracy

0.01ppm

DO sensor

Amperometric gold/silver membrane type

Temperature sensor

Pt100

Temperature display range

0–100°C

Temperature compensation

Manual

Temperature range

0–55°C

Temperature resolution

0.1°C

Temperature accuracy

0.1°C

Calibration

Manual

Power supply

230 V AC ±10%, 50 Hz