Description
Digital Photo Fluorometer – Reliable Fluorescence Measurement for Laboratory Applications
The JIPL Digital Photo Fluorometer is a precision laboratory instrument developed for measuring fluorescence intensity and determining the concentration of fluorescent substances in liquid samples. It works on the principle of fluorometry, in which a sample is exposed to excitation light and the emitted fluorescence is detected and measured by a sensitive detector.
Fluorescence measurement is widely used in analytical chemistry, pharmaceutical testing, biochemical research and environmental analysis. Since certain substances emit light when exposed to suitable excitation wavelengths, their fluorescence intensity can be used to estimate their concentration under controlled testing conditions.
The JIPL Digital Photo Fluorometer is designed to support these measurement requirements through a stable excitation source, optical filter arrangement, sensitive photodiode detector and digital display. Its straightforward operation makes it suitable for laboratories that perform routine fluorescence analysis and concentration determination.
1. Sensitive Fluorescence Detection
The instrument incorporates a highly sensitive, wide-range photodiode detector/cell for detecting fluorescence signals from the tested sample. The detector converts the received light into an electrical signal, which is processed and displayed as a measurement reading.
A sensitive detection system is important in fluorometric analysis because fluorescence signals can vary considerably depending on the sample concentration and composition. The instrument is designed to support reliable detection across its specified sensitivity ranges.
2. Tungsten Halogen Excitation Light Source
The JIPL Digital Photo Fluorometer uses a 12V, 50W tungsten halogen lamp as its excitation source. The lamp provides the illumination required for exciting fluorescent substances in the sample.
The sample is exposed to the selected excitation light through the instrument’s primary filter arrangement. The resulting fluorescence is then separated and measured through the secondary optical filter system. This arrangement helps the instrument distinguish the fluorescence signal from the excitation light for the selected analytical procedure.
3. Primary and Secondary Optical Filters
The instrument is supplied with primary and secondary optical filters mounted on holders. These filters help select the appropriate excitation and emission light bands for different fluorescence measurement requirements.
The specified primary filters are Corning 5840 and Corning 5113, while the secondary filters include Corning 4308, Corning 3486 and Corning 3385.
The combination of these filters allows users to select suitable optical configurations for compatible fluorescent samples and analytical methods. Correct filter selection is important for obtaining meaningful and repeatable fluorescence readings.
4. Four Adjustable Sensitivity Ranges
The JIPL Digital Photo Fluorometer provides sensitivity adjustment across four ranges. This feature allows operators to select an appropriate sensitivity setting according to the fluorescence intensity of the sample being tested.
Different samples may produce different fluorescence signals depending on their concentration and chemical characteristics. Adjustable sensitivity helps accommodate variations in signal strength and makes the instrument useful for different routine testing requirements.
Users should select the appropriate range and follow the recommended calibration procedure for the sample and analytical method.
5. Clear Digital LED Display
The instrument features a 3-digit bright red seven-segment LED display for presenting measurement readings. The display is designed for convenient observation during routine laboratory testing.
Its straightforward digital indication helps operators read results without relying on analogue scales. The simple display arrangement also makes the instrument suitable for laboratory personnel, technicians and students performing regular fluorescence measurements.
6. Low Sample Volume Requirement
The JIPL Digital Photo Fluorometer requires a minimum sample volume of only 4 ml, making it suitable for testing applications where sample availability is limited.
The instrument uses a sample test tube measuring 15 mm diameter × 80 mm height. This sample arrangement supports convenient sample placement during measurement. Users should use compatible, clean sample tubes and follow the recommended preparation and handling procedure to minimise measurement errors.
7. Concentration Determination
The instrument is capable of determining the concentration of fluorescent substances through fluorescence measurement. In fluorometric analysis, fluorescence intensity can be related to the concentration of a substance using an appropriate calibration procedure.
For quantitative analysis, users generally prepare reference standards of known concentration, establish a calibration relationship and measure the unknown sample under the same operating conditions. The accuracy of concentration determination depends on the sample properties, calibration standards, filter selection and testing procedure.
8. Applications Across Multiple Industries
The JIPL Digital Photo Fluorometer is suitable for a variety of laboratory and analytical applications, including:
- Pharmaceutical Laboratories: Fluorescence-based testing of suitable pharmaceutical compounds and prepared samples.
- Chemical Laboratories: Analysis of fluorescent chemicals and concentration determination.
- Biochemical Research: Fluorescence measurement of compatible biochemical samples.
- Educational Institutions: Practical demonstrations and experiments involving fluorescence principles.
- Research Laboratories: Supporting analytical research and sample evaluation.
- Environmental Testing: Fluorometric analysis of suitable environmental and water samples using validated methods.
- Food and Beverage Laboratories: Testing of fluorescent compounds and selected sample constituents.
- Quality Control Departments: Routine fluorescence measurements and concentration-related testing.
9. Compact Construction and Convenient Operation
The instrument is designed for tabletop laboratory installation. Its compact dimensions of approximately 255 × 300 × 145 mm and approximate weight of 5 kg make it convenient to position on a laboratory workbench.
It operates on a 230 V ±10%, 50 Hz AC power supply. The supplied accessories include a set of five primary and secondary filters, an instruction manual and a dust cover. These accessories support routine operation, filter selection and instrument maintenance.
10. A Practical Solution for Fluorometric Analysis
The JIPL Digital Photo Fluorometer combines a tungsten halogen excitation lamp, sensitive photodiode detector, optical filter arrangement and adjustable sensitivity settings in one laboratory instrument. Its 4 ml minimum sample requirement and digital LED display make it a practical choice for routine fluorescence testing.
For pharmaceutical laboratories, chemical testing facilities, research centres, educational institutions and industrial quality control departments, this instrument provides a convenient solution for fluorescence intensity measurement and concentration determination using suitable analytical methods.
Standard Accessories
| Accessory | Details |
|---|---|
| Primary Filters | Corning 5840 and Corning 5113 |
| Secondary Filters | Corning 4308, Corning 3486 and Corning 3385 |
| Filter Set | Set of 5 Primary and Secondary Filters |
| Instruction Manual | Included |
| Dust Cover | Included |
Japsin Instrumentation – Since 1974
Reviews
There are no reviews yet.