Digital Turbidity Meter – Laboratory Turbidity Measurement ( JIPL-462 )

₹5,200.00

Available on back-order

Compare
SKU: JIPL-462 Category:

Your Gateway to Precision Control. Explore Our Online Store for Cutting-edge Instrumentation Solutions. Reliable Quality, Unparalleled Performance.

Explore JIPL Digital Turbidity Meters for laboratory water testing. Available in 0–200 NTU/JTU ranges with LED display and manual calibration.

Japsin Instrumentation – Since 1974

Description

Digital Turbidity Meter – Laboratory Turbidity Measurement

The JIPL Digital Turbidity Meter is designed for measuring the turbidity or cloudiness of water and liquid samples in laboratory and water-quality testing applications. It provides digital turbidity readings in NTU/JTU and is available in three model variants to accommodate different measurement ranges and resolution requirements.

Turbidity is an important parameter in water analysis because it indicates the presence of suspended particles such as clay, silt, organic matter and other fine materials. Monitoring turbidity helps laboratories, water treatment facilities, environmental testing teams and industrial quality-control departments assess the clarity of water and observe changes in sample conditions.

The instrument is available in three models: JIPL-466, JIPL-462 and JIPL-422. These models offer measurement ranges of up to 1000 NTU/JTU or 200 NTU/JTU, depending on the selected version. All three models feature a 3½-digit, 7-segment LED display, a tungsten lamp light source, a silicon photodiode detector and manual two-point calibration.

Reliable Digital Turbidity Measurement

The JIPL Digital Turbidity Meter is developed for routine measurement of turbidity in liquid samples. Turbidity measurements help determine the relative clarity of water by assessing the effect of suspended particles on light passing through or interacting with the sample.

The instrument uses a 6V tungsten lamp as its light source and a silicon photodiode as its detector. This optical measurement arrangement supports the instrument’s digital turbidity measurement function. The measured value is displayed on a 3½-digit, 7-segment LED display, making it convenient for laboratory personnel to observe and record readings.

Depending on the application, users can select a model with a measurement range of 0 to 1000 NTU/JTU or 0 to 200 NTU/JTU. This model selection allows laboratories to choose an instrument according to their expected sample turbidity levels and desired measurement resolution.

Three Model Options for Different Testing Requirements

The product range includes three models with different measurement specifications.

  • JIPL-466: Offers a measurement range of 0 to 1000 NTU/JTU with a resolution of 1 NTU/JTU. It is suitable for applications where a wider turbidity measurement range is required.

  • JIPL-462: Offers a measurement range of 0 to 200 NTU/JTU with a resolution of 0.1 NTU/JTU. It provides finer display resolution for lower-range turbidity testing.

  • JIPL-422: Also offers a measurement range of 0 – 200 NTU/JTU / 0 – 1000 NTU/JTU with a resolution of 0.1 NTU/JTU / 1 NTU/JTU.

All three models have a stated accuracy of ±3% of full scale (FS), ±1 digit. The availability of these variants makes it easier to select a model based on the expected turbidity levels of the samples being tested.

Optical Measurement System

The instrument incorporates a 6V tungsten lamp and a silicon photodiode detector. The lamp provides the light source required for the optical measurement system, while the detector responds to the light signal associated with the sample measurement.

The optical system is housed in a compact instrument body designed for laboratory use. Samples are placed in a 30 mm clear glass test tube, which provides a defined sample container for measurement. Using clean and suitable test tubes is important because fingerprints, scratches, air bubbles or residue on the glass surface may affect optical readings.

For consistent results, users should follow the recommended sample preparation and measurement procedures. The same type of test tube should be used consistently where required by the instrument’s operating procedure.

Manual Two-Point Calibration

The JIPL Digital Turbidity Meter supports manual two-point calibration. Calibration is an important step in maintaining measurement reliability and ensuring that the instrument is adjusted according to the required reference standards.

Users should perform calibration using appropriate turbidity reference solutions and follow the manufacturer’s instructions for the selected model. The calibration procedure should be repeated at suitable intervals, particularly when the instrument is being used for regular quality-control testing or when measurement conditions change.

Proper calibration, clean test tubes and consistent sample handling help improve the reliability and repeatability of routine turbidity measurements.

Clear LED Display and Convenient Operation

The instrument features a 3½-digit, 7-segment LED display for presenting turbidity readings. Its digital display makes readings easy to observe during routine testing and helps reduce the inconvenience associated with interpreting analogue scales.

The instrument is designed with a compact laboratory configuration. Its approximate weight is 1.5 kg, and its dimensions are 275 × 195 × 105 mm. This construction makes it convenient to position on a laboratory workbench and suitable for routine testing environments.

The instrument is supplied with a dust cover, operation manual and three 30 mm clear glass test tubes. These accessories support basic instrument operation and sample testing.

Applications of Digital Turbidity Meter

Turbidity measurement is relevant to several industries and laboratory activities where water clarity and suspended particles need to be monitored.

  • Drinking water testing: Checking the turbidity of treated and untreated water samples.

  • Water treatment plants: Monitoring water clarity during different treatment stages.

  • Wastewater treatment: Assessing turbidity changes during wastewater treatment processes.

  • Environmental laboratories: Supporting water-quality testing of rivers, lakes, ponds and other water sources.

  • Industrial water testing: Monitoring turbidity in process water and utility water systems.

  • Educational institutions: Conducting practical experiments and demonstrations related to water analysis.

  • Research laboratories: Performing routine turbidity measurements for water-related research.

  • Food and beverage industries: Supporting applicable water-quality checks in production and utility processes.

Easy Maintenance and Routine Care

For dependable performance, the instrument should be operated in accordance with the manufacturer’s instructions. Test tubes should be kept clean and free from scratches, fingerprints and sample residue. Samples should be prepared consistently, and visible air bubbles should be avoided where they may interfere with optical measurement.

The instrument should be calibrated using suitable reference solutions as specified in its operating procedure. After use, clean the test tubes appropriately, protect the instrument from dust and store it in a suitable environment.

The supplied dust cover helps protect the instrument when it is not in use. Routine care of the optical components and sample containers can help maintain measurement consistency.

A Practical Instrument for Laboratory Water Analysis

The JIPL Digital Turbidity Meter range provides three model options for laboratories and water-quality testing facilities. With a tungsten lamp optical system, silicon photodiode detector, manual two-point calibration and digital LED display, the instrument is designed for routine turbidity measurement.

Whether the requirement is a wider measurement range or finer display resolution for lower turbidity samples, users can select from the JIPL-466, JIPL-462 and JIPL-422 variants according to their testing needs. Its compact construction and supplied glass test tubes make it a practical choice for laboratory-based water analysis and quality-control applications.

Japsin Instrumentation – Since 1974

Additional information

Brand

"Ji" Japsin Instrumentation

Model

JIPL-462

Instrument Type

Digital Turbidity Meter

Turbidity Range

0 to 200 NTU/JTU

Resolution

0.1 NTU/JTU

Accuracy

±3% FS, ±1 digit

Test Tube System

30 mm clear glass test tube

Light Source

6V Tungsten Lamp

Detector

Silicon Photodiode

Calibration

Manual / 2 Point

Display

3½-Digit 7-Segment LED

Approx. Weight

1.5 kg

Dimensions

275 × 195 × 105 mm

Accessories

Dust cover, operation manual, 3 × 30 mm glass test tubes

Reviews

There are no reviews yet.

Be the first to review “Digital Turbidity Meter – Laboratory Turbidity Measurement ( JIPL-462 )”