Fluorescence Spectrophotometer ( JIPL-4000 )

₹709,900.00

Available on back-order

Compare
SKU: JIPL-4000 Category:

Your Gateway to Precision Control. Explore Our Online Store for Cutting-edge Instrumentation Solutions. Reliable Quality, Unparalleled Performance.

Fluorescence Spectrophotometer with xenon lamp, single-beam optical system, 1 nm spectral bandwidth and wavelength range up to 900 nm.

Japsin Instrumentation – Since 1974

Description

Fluorescence Spectrophotometer – High-Sensitivity Fluorescence Analysis

The JIPL Fluorescence Spectrophotometer is an advanced analytical instrument developed for measuring fluorescence signals from chemical and biological samples. It operates on the principle of fluorescence spectroscopy, in which a sample absorbs light at a selected excitation wavelength and emits light at a longer wavelength. The emitted light is detected and analysed to study the fluorescent properties of the sample.

Fluorescence spectroscopy is widely used in analytical chemistry, pharmaceutical research, biochemical studies, environmental testing and quality control applications. It is particularly useful for detecting and analysing substances that produce measurable fluorescence under suitable excitation conditions.

The JIPL Fluorescence Spectrophotometer is designed to provide reliable optical measurement through its single-beam arrangement, xenon lamp source and high-sensitivity optical system. With two available configurations, users can select a model according to their wavelength requirements and preferred display or computer interface.

1. Fluorescence Measurement and Analytical Performance

The instrument is designed for the detection and analysis of fluorescent compounds. It supports fluorescence-related analytical work by measuring optical signals generated when samples are exposed to selected excitation light.

Fluorescence measurements can help researchers identify fluorescent characteristics and determine the concentration of suitable substances through appropriate calibration procedures. The instrument can be used for routine laboratory testing, comparative sample analysis and research applications.

Its measurement capabilities also include optical modes such as absorbance, transmittance and concentration, with additional measurement modes available on the JIPL-4000 configuration.

2. Two Model Options for Different Laboratory Requirements

The JIPL Fluorescence Spectrophotometer is available in two configurations:

JIPL-4000 Fluorescence Spectrophotometer: This model offers a wavelength range of 200–650 nm and PC-controlled operation. Its listed measurement modes include absorbance, kinetics, transmittance, concentration and reflectance. It is suitable for laboratories requiring computer-based instrument operation and a range of optical measurement functions.

JIPL-4100 Fluorescence Spectrophotometer: This model provides an extended wavelength range of 200–900 nm and features an LCD display. Its listed measurement modes include concentration, absorbance and transmittance. It is suitable for laboratories requiring a broader specified wavelength range and direct display-based operation.

Both configurations feature a single-beam optical system and a specified spectral bandwidth of 1 nm.

3. Xenon Lamp Light Source

The JIPL Fluorescence Spectrophotometer uses a xenon lamp as its light source. Xenon lamps are commonly used in laboratory optical instruments because of their broad spectral output, making them suitable for applications requiring illumination across different wavelength regions.

The optical system uses the selected light to excite fluorescent compounds in the sample. The resulting emitted light is measured by the instrument’s detection system. This arrangement supports fluorescence analysis across the operating wavelength range of the selected model.

4. Single-Beam Optical Configuration

The instrument uses a single-beam optical arrangement for optical measurements. In this configuration, light passes through the selected optical path and sample, and the resulting signal is measured by the instrument.

A suitable blank or reference measurement is important for obtaining reliable results. Users should follow the recommended operating and calibration procedure for their particular sample and analytical method.

5. High Wavelength Accuracy and Repeatability

Wavelength accuracy and repeatability are important specifications in spectrophotometric analysis because they influence the consistency of measurements at selected wavelengths.

The JIPL-4000 offers wavelength accuracy of ±1.0 nm and wavelength repeatability of ±0.3 nm. The JIPL-4100 provides wavelength accuracy of ±0.3 nm and wavelength repeatability of ±0.1 nm.

Both models have a specified spectral bandwidth of 1 nm, supporting wavelength-selective optical measurements in laboratory applications.

6. Photometric Measurement Capabilities

The instrument provides optical measurement functions to support different laboratory testing requirements. The JIPL-4000 includes absorbance, kinetics, transmittance, concentration and reflectance modes, while the JIPL-4100 includes concentration, absorbance and transmittance modes.

The listed photometric accuracy for both models is ±0.3% T. These measurement facilities support optical analysis and sample evaluation when appropriate standards, reference solutions and validated procedures are used.

7. Computer Interface and Display Facilities

The JIPL-4000 features PC-controlled operation, while the JIPL-4100 is equipped with an LCD display. Both configurations provide an RS-232 interface for communication with compatible external equipment.

The PC-controlled arrangement of the JIPL-4000 is useful for laboratories that prefer computer-assisted operation and data handling. The LCD display of the JIPL-4100 provides a direct instrument display for routine measurements.

Software availability, compatibility and specific data-processing functions should be confirmed for the selected model before purchase.

8. Applications Across Multiple Industries

The JIPL Fluorescence Spectrophotometer is suitable for a wide range of laboratory applications, including:

  • Pharmaceutical Laboratories: Fluorescence-based analysis of suitable pharmaceutical compounds and prepared samples.
  • Clinical Laboratories: Supporting optical analysis of compatible clinical and biochemical samples.
  • Chemical Industries: Studying fluorescent chemical compounds and performing concentration-related measurements.
  • Environmental Laboratories: Supporting fluorescence analysis of suitable environmental and water samples.
  • Food Laboratories: Testing selected fluorescent substances and sample constituents.
  • Academic Institutions: Supporting practical experiments and research in analytical chemistry and spectroscopy.
  • Biomolecular Research: Analysing suitable fluorescent compounds and biomolecular samples.
  • Quality Control Departments: Performing routine optical measurements and sample comparisons.

9. A Versatile Solution for Laboratory Analysis

The JIPL Fluorescence Spectrophotometer combines a xenon lamp source, single-beam optical configuration, 1 nm spectral bandwidth and multiple measurement modes in a laboratory instrument. Its two model configurations provide flexibility in wavelength range and display arrangement.

For pharmaceutical manufacturers, chemical laboratories, research centres, clinical facilities and educational institutions, the JIPL-4000 and JIPL-4100 provide practical options for fluorescence-related analytical work and optical sample measurement.

Key Features

  • High-sensitivity fluorescence analysis
  • Single-beam optical configuration
  • Xenon lamp light source
  • 1 nm spectral bandwidth
  • Multiple optical measurement modes
  • RS-232 communication interface
  • PC-controlled operation on JIPL-4000
  • LCD display on JIPL-4100
  • Suitable for laboratory, pharmaceutical, chemical and research applications

Japsin Instrumentation – Since 1974

Additional information

Brand

"Ji" Japsin Instrumentation

Product Type

Fluorescence Spectrophotometer

Application Type

Fluorescence

Optical System

Single Beam

Wavelength Range

200–650 nm

Spectral Bandwidth

1 nm

Wavelength Accuracy

±1.0 nm

Wavelength Repeatability

±0.3 nm

Photometric Accuracy

±0.3% T

Photometric Range

250–600 nm

Display / Operation

PC Controlled

Measurement Modes

Absorbance, Kinetics, Transmittance, Concentration, Reflectance

Interface

RS-232

Light Source

Xenon Lamp

Power Supply

230 V AC

Instrument Type

Benchtop

Reviews