Leak Test Apparatus ( JIPL-1353-1 )

₹76,500.00

Available on back-order

Compare
SKU: JIPL-1353-1 Category:

Your Gateway to Precision Control. Explore Our Online Store for Cutting-edge Instrumentation Solutions. Reliable Quality, Unparalleled Performance.

Explore Japsin Instrumentation Leak Test Apparatus for vacuum-based packaging integrity testing of blister packs, strips, sachets and sealed containers.

Japsin Instrumentation – Since 1974

 

Description

Leak Test Apparatus

The Leak Test Apparatus by Japsin Instrumentation is a laboratory testing instrument developed for evaluating the integrity of sealed packages and detecting possible leakage in flexible packaging and other suitable containers. It is used in quality-control laboratories to assess packaging performance and verify whether seals provide the required protection against external contamination and product leakage.

Packaging integrity is an important quality parameter in industries such as pharmaceuticals, food processing, chemicals and healthcare products. A defective seal, pinhole or weak packaging joint can allow moisture, air, contaminants or other external substances to enter the package. Such defects may affect product quality, shelf life, safety and storage stability. The Leak Test Apparatus provides a practical vacuum-based testing method to help identify these packaging defects.

Working Principle of Leak Test Apparatus

The instrument works on the vacuum leak testing principle. The test samples are placed inside a transparent polycarbonate desiccator chamber, which is connected to a vacuum pump. The pump removes air from the chamber and creates the required vacuum level.

The vacuum is maintained for a predetermined holding period. After the test period is completed, the vacuum is released. During this process, any leakage path in the packaging may allow air or liquid to pass through the defective area, depending on the test arrangement.

For dye penetration testing, the packaging samples are immersed in a coloured dye solution, commonly methylene blue. When the vacuum is released, dye may enter through openings or defective seals. The presence of dye inside the package can indicate a possible leakage point.

This method is particularly useful for examining sealed flexible packaging, including blister packs, strips and sachets. The testing procedure and acceptance criteria should be selected according to the packaging material, product characteristics and applicable quality-control method.

Polycarbonate Desiccator Chamber

The Leak Test Apparatus is supplied with a polycarbonate desiccator chamber designed to withstand the vacuum conditions required for testing. The transparent chamber allows the operator to observe the test samples during the procedure.

The manufacturer lists a 10-inch desiccator with all three models. Optional accessories include 8-inch and 12-inch desiccators, as well as a 1.5-metre silicon output pipe. These options allow laboratories to consider different chamber and accessory requirements.

The chamber provides an enclosed environment for conducting vacuum-based packaging tests. Its transparent construction supports visual observation of the samples and the testing process.

Vacuum Generation and Holding

A compact vacuum pump is used to create a vacuum inside the desiccator chamber. According to the manufacturer, the pump is designed to generate a high vacuum level in a short period.

Once the required vacuum condition is established, it is maintained for the selected testing duration. This holding period allows the operator to evaluate the behaviour of the packaging under vacuum conditions.

The instrument includes timer functions for monitoring the pump running time and vacuum holding or testing time, depending on the selected model. These timer functions support controlled testing procedures and help laboratory personnel monitor the duration of each test.

Automatic and Manual Operating Configurations

The Leak Test Apparatus is available in three model configurations to meet different laboratory operating preferences.

JIPL-1353-1 – Automatic Leak Test Apparatus

The JIPL-1353-1 is an automatic configuration featuring microprocessor-based control and digital dual display. It provides separate timer displays for vacuum pump running time and vacuum holding or testing time. The manufacturer specifies automatic operation without manual valve operation. Audio and visual alarms are also provided to indicate operating conditions.

JIPL-1353-2 – Manual Leak Test Apparatus

The JIPL-1353-2 is a manual configuration with a two-valve operating arrangement. It features a digital dual display for monitoring vacuum pump running time and vacuum holding or testing time. Manual valve operation allows the operator to control the testing sequence. Audio and visual alarms are included.

JIPL-1353-3 – Manual Leak Test Apparatus

The JIPL-1353-3 is a manual configuration equipped with a single-valve operating arrangement. It includes a single digital display for the vacuum holding or testing timer, with a maximum indicated time of 99 hours and 59 minutes. The instrument also features audio and visual alarms.

All three configurations are specified with a stainless-steel body and a 10-inch desiccator chamber.

Digital Timer and Alarm Indication

The digital timer functions help operators monitor the duration of vacuum generation and the vacuum holding period. The JIPL-1353-1 and JIPL-1353-2 models feature dual displays, allowing the pump running time and vacuum holding time to be viewed separately.

The JIPL-1353-3 model uses a single digital display for vacuum holding or testing time. The manufacturer specifies a maximum timer display of 99 hours and 59 minutes.

Audio and visual alarm facilities are included across the three models to provide operating alerts. These features support monitoring during routine laboratory testing.

Stainless-Steel Construction

The instrument is specified with a stainless-steel body, making it suitable for use in laboratory and industrial quality-control environments. The transparent polycarbonate desiccator provides visibility of the test samples, while the stainless-steel construction forms the main instrument body.

The combination of a vacuum chamber, pump and model-specific control arrangement provides a dedicated setup for packaging leak testing.

Applications of Leak Test Apparatus

The Leak Test Apparatus is suitable for packaging integrity testing in various industries:

  • Pharmaceutical industry: Testing the integrity of blister packs, tablet strips, sachets and other pharmaceutical packaging.
  • Food industry: Checking seals in food packets, pouches and flexible packaging.
  • Chemical industry: Evaluating the sealing integrity of suitable chemical product packaging.
  • Healthcare and medical products: Examining suitable sealed packages for possible leakage.
  • Quality-control laboratories: Conducting routine packaging inspection and seal-integrity testing.
  • Packaging industries: Evaluating sealing performance and identifying possible packaging defects.

Why Choose Japsin Instrumentation Leak Test Apparatus?

The Leak Test Apparatus provides a vacuum-based approach to examining the integrity of sealed packaging. Its three available configurations offer a choice between automatic operation, manual dual-valve operation and manual single-valve operation.

Features such as a transparent polycarbonate desiccator, vacuum pump, digital timer displays, stainless-steel body and audio-visual alarms support laboratory packaging inspection procedures.

For pharmaceutical, food, chemical and industrial laboratories, the instrument can be considered for routine evaluation of packaging seals and possible leakage defects. Selecting the appropriate model depends on the required operating arrangement, testing workflow and laboratory requirements.

Japsin Instrumentation offers laboratory and industrial testing instruments designed to support quality-control and measurement applications across different industries.

General Specifications

Parameter Specification
Product Name Leak Test Apparatus
Available Models SKY-1353-1, SKY-1353-2, SKY-1353-3
Testing Principle Vacuum leak testing
Application Leakage testing of sealed packaging
Display Digital display; single or dual depending on model
Maximum Timer Display 99 hours and 59 minutes
Desiccator Material Polycarbonate
Standard Desiccator Size 10 inches
Instrument Body Stainless steel (SS)
Vacuum Generation Compact vacuum pump
Alarm Audio and visual alarm
Optional Desiccators 8-inch and 12-inch
Optional Output Pipe Silicon pipe, 1.5 metres

Optional Accessories

Accessory Specification
Desiccator 8 inches
Desiccator 10 inches (standard)
Desiccator 12 inches
Silicon Pipe (Output) 1.5 metres

Japsin Instrumentation – Since 1974

Additional information

Brand

"Ji" Japsin Instrumentation

Product Name

Leak Test Apparatus

Model

JIPL-1353-1

Model Type

Automatic

Operating System

Microprocessor-based

Display

Digital dual display

Pump Running Time Display

Yes

Vacuum Holding Time Display

Yes

Maximum Timer Display

99 hr 59 min

Valve Operation

Automatic, no manual valve operation

Audio Alarm

Yes

Visual Alarm

Yes

Body Construction

Stainless steel

Desiccator

10 inches