Description
Microprocessor Conductivity, TDS, Salinity & Temperature Meter
The JIPL Microprocessor Conductivity, TDS, Salinity & Temperature Meter is a versatile digital water quality testing instrument designed for accurate measurement of electrical conductivity (EC), Total Dissolved Solids (TDS), salinity and temperature. Equipped with microprocessor-based measurement technology, this instrument provides reliable readings, convenient operation and multiple measurement functions in a single unit. It is suitable for laboratories, industrial quality control departments, water treatment facilities, educational institutions and research applications where monitoring water quality parameters is essential.
Designed to simplify routine testing and measurement procedures, this Microprocessor Conductivity TDS Salinity Temperature Meter combines automatic ranging, adjustable calibration parameters, temperature compensation and sample data storage. Its multifunctional design allows operators to evaluate different water quality characteristics without requiring separate instruments for each parameter.
1. Four Measurement Functions in One Instrument
One of the major advantages of the JIPL Microprocessor Meter is its ability to measure four important parameters: conductivity, TDS, salinity and temperature.
Conductivity Measurement (EC): Electrical conductivity indicates the ability of water to conduct electrical current, which is influenced by the concentration of dissolved ionic substances. The instrument offers a conductivity measurement range from 0.00 µS/cm to 100 mS/cm across six automatic ranges. This makes it useful for testing samples with different conductivity levels, including low-conductivity water and more concentrated solutions.
Total Dissolved Solids (TDS): TDS measurement helps estimate the concentration of dissolved substances in water. The meter provides a measurement range from 0.00 ppm to 200 ppt across five automatic ranges. Its adjustable TDS conversion factor allows users to configure the calculation according to their testing requirements.
Salinity Measurement: Salinity measurement is important for determining the salt concentration in water samples. The instrument measures salinity from 0.0 ppt to 50 ppt, with a resolution of 0.1 ppt. The salinity factor is manually adjustable, providing flexibility for different sample measurement requirements.
Temperature Measurement: Temperature measurement is integrated into the instrument to support water quality analysis and temperature compensation. With a Pt100 temperature probe, the meter measures temperatures from -20°C to +200°C.
2. Automatic Temperature Compensation
Temperature can significantly influence conductivity readings. To improve measurement consistency, the JIPL meter provides automatic temperature compensation (ATC) from 0°C to 70°C when used with the temperature probe. Manual temperature compensation is also available through the instrument’s keys.
The temperature compensation adjustment is configurable from 0.00% to 4%, with a default setting of 2%. Users can also select a reference temperature of 20°C or 25°C according to their measurement procedure. These features help compensate for temperature-related variations during conductivity testing.
3. Microprocessor-Based Operation and Automatic Ranging
The instrument uses microprocessor-based control to manage measurement functions and provide convenient operation. Its automatic ranging capability selects the appropriate measurement range according to the sample being tested. This reduces the need for frequent manual range selection and supports efficient testing across different concentration levels.
The conductivity cell constant can be digitally adjusted from 0.05 to 2.000, with 1.000 as the default setting. The TDS factor has a default value of 0.50 and can be adjusted manually, while the salinity factor has a default value of 0.75 and is also adjustable.
4. Data Storage, Date and Time Display
For laboratories and quality control environments that require measurement records, the instrument offers a storage capacity of up to 100 samples. Data entry is performed through six soft-touch keys with audible feedback, making operation straightforward.
The meter also displays real-time date and time in a 24-hour format. This helps users associate recorded measurements with their testing schedule and maintain organised sample information.
5. Computer Interface and Printing Facility
The JIPL Microprocessor Conductivity TDS Salinity Temperature Meter includes RS-232 and Centronics computer interfaces for data communication and printing-related applications. Users can select printing records date-wise or print all stored data, supporting documentation and record-keeping requirements.
The print format can include the date, time, temperature, measured parameter, operating mode and sample number. This is particularly useful in laboratories and industrial environments where measurement traceability and documented test results are important.
6. Applications Across Multiple Industries
The instrument can be used in a wide range of water testing and quality monitoring applications, including:
- Water Treatment Plants: Monitoring conductivity, TDS and salinity during water treatment processes.
- Laboratories: Performing routine water quality analysis and sample testing.
- Pharmaceutical Industries: Supporting water quality monitoring as part of laboratory and process checks.
- Chemical Industries: Measuring conductivity and dissolved solids in process water and prepared solutions.
- Food and Beverage Industries: Checking water quality used in production and cleaning operations.
- RO and DM Water Systems: Monitoring changes in conductivity and TDS during water purification.
- Aquaculture and Environmental Testing: Measuring salinity and other water quality parameters in relevant samples.
- Educational and Research Institutions: Supporting practical experiments, research and water analysis.
7. Complete Accessories and Convenient Installation
The instrument is supplied with a conductivity cell, temperature probe and instruction manual. These accessories support the instrument’s conductivity and temperature measurement functions and help users begin routine testing after installation and setup.
8. A Practical Solution for Water Quality Measurement
The JIPL Microprocessor Conductivity, TDS, Salinity & Temperature Meter combines multiple measurement functions, adjustable compensation settings, sample storage and data communication capabilities in one instrument. Its automatic ranging, Pt100 temperature probe and configurable measurement factors make it a practical choice for users who need to monitor different water quality parameters.
For laboratories, industrial facilities and water treatment applications, this multifunction digital meter offers a convenient approach to routine measurement, sample evaluation and record management. It is an effective solution for organisations looking for a single instrument to support conductivity, TDS, salinity and temperature testing.
Japsin Instrumentation – Since 1974

Reviews