Microprocessor Single Beam Visible Spectrophotometer with Software
The JIPL Microprocessor Single Beam Visible Spectrophotometer with Software is a versatile laboratory instrument developed for measuring the optical properties of liquid samples using visible light. It operates on the principle of spectrophotometry, where light of a selected wavelength passes through a sample and the instrument measures the amount of light absorbed or transmitted.
Visible spectrophotometry is widely used in analytical chemistry, pharmaceutical testing, environmental monitoring, food analysis and industrial quality control. It helps determine the concentration of suitable substances by measuring their light absorption characteristics at selected wavelengths.
Designed with microprocessor-based operation and a reliable single-beam optical system, the JIPL Visible Spectrophotometer combines convenient measurement functions, direct concentration readout and computer connectivity. It is suitable for laboratories, research institutions, educational organisations and industrial testing facilities that require dependable routine optical analysis.
1. Wide Visible Wavelength Range
The instrument operates over a wavelength range of 320 nm to 1020 nm, covering the visible region and extending into the near-infrared boundary of the specified range.
This broad wavelength coverage allows users to select suitable wavelengths according to the absorption characteristics of the sample being tested. The instrument offers a wavelength interval of 1 nm and wavelength accuracy of ±2 nm, supporting convenient wavelength selection for different analytical procedures.
2. Advanced Single-Beam Optical System
The JIPL Visible Spectrophotometer uses a C-T single-beam optical system with a 1200 lines/mm grating monochromator. The monochromator separates light into individual wavelength components, allowing the required wavelength to be selected for measurement.
The instrument uses a holographic grating arrangement designed to provide high wavelength precision, good monochromatic performance and low stray light. These optical characteristics support consistent measurement results when the instrument is operated under suitable laboratory conditions.
3. Tungsten Lamp Light Source
The instrument is equipped with a tungsten lamp as its light source. Tungsten lamps provide illumination suitable for visible-region spectrophotometric measurements.
The selected light passes through the monochromator and sample compartment before reaching the detector. This optical arrangement allows the instrument to measure the transmitted light and calculate the corresponding absorbance or transmittance values.
4. Three Measurement Modes
The JIPL Microprocessor Visible Spectrophotometer supports three measurement modes to meet different laboratory requirements.
Transmittance (T): Measures the percentage of light passing through the sample. This mode is useful for evaluating the transparency and light-transmission characteristics of solutions.
Absorbance (A): Measures the amount of light absorbed by a sample at a selected wavelength. Absorbance is widely used for quantitative chemical analysis and concentration determination.
Concentration (C): Provides a direct concentration readout facility. Users can set a concentration factor to support routine quantitative analysis without manually converting every absorbance reading.
5. Direct Concentration Readout and Factor Setting
One of the useful features of this instrument is its direct concentration measurement facility. The concentration factor setting function allows users to configure the instrument according to their analytical method.
This feature is particularly helpful in laboratories performing repeated measurements of samples using established calibration procedures. For reliable quantitative results, the concentration factor should be determined using suitable reference standards and validated analytical methods.
6. Reliable Photometric Performance
The instrument provides a photometric measurement range of 0–1.999 absorbance units and 0–199.9% transmittance. Its specified photometric accuracy is ±1% T, while photometric repeatability is 0.5% T.
The spectral bandwidth is 2 nm, and stray light is specified at ≤0.3% T at 340 nm. The instrument also offers stability of ±0.004 A/h at 500 nm.
These specifications make it suitable for routine laboratory measurements where consistent optical readings and repeatability are important.
7. Silicon Photodiode Detector and LCD Display
The JIPL Visible Spectrophotometer incorporates a silicon photodiode detector to detect transmitted light and convert the optical signal into an electrical measurement.
The instrument features a four-digit LCD display for presenting measurement information. The digital display helps laboratory operators observe readings conveniently during routine testing and sample analysis.
8. Sample Compartment and Cuvette Compatibility
The instrument features a sample compartment equipped with a 50 mm cell holder. It is also supplied with four 10 mm glass cells for routine sample testing.
The selection of an appropriate cuvette depends on the sample properties, measurement wavelength and analytical procedure. A suitable path length helps maintain consistent optical measurement conditions during testing.
9. Software and RS-232 Computer Connectivity
The instrument is supplied with a software CD and RS-232 communication cable. Its RS-232C interface allows connection to compatible external computer systems for supported data communication.
Computer connectivity can be useful in laboratories where measurement information needs to be transferred or documented. The supplied software should be installed and operated according to its instructions, and compatibility with the laboratory computer should be confirmed before use.
10. Applications Across Multiple Industries
The JIPL Microprocessor Single Beam Visible Spectrophotometer is suitable for various laboratory and industrial applications, including:
- Pharmaceutical Laboratories: Spectrophotometric testing of suitable pharmaceutical compounds and prepared solutions.
- Chemical Industries: Measurement of absorbance and concentration of chemical samples.
- Water and Wastewater Laboratories: Analysis of prepared water samples using suitable spectrophotometric methods.
- Food and Beverage Laboratories: Testing selected compounds and sample constituents through validated analytical procedures.
- Environmental Monitoring: Supporting optical analysis of environmental samples.
- Agricultural Chemistry: Laboratory testing of prepared agricultural and chemical samples.
- Educational Institutions: Practical demonstrations and experiments in analytical chemistry.
- Metallurgy and Geology: Supporting spectrophotometric analysis of suitable prepared samples.
- Petrochemical Industries: Laboratory testing and quality control of selected solutions.
- Industrial Quality Control: Routine sample evaluation and concentration measurement.
11. A Practical Solution for Laboratory Spectrophotometry
The JIPL Microprocessor Single Beam Visible Spectrophotometer with Software combines a wide wavelength range, holographic grating monochromator, tungsten lamp, silicon photodiode detector and direct concentration readout in one laboratory instrument.
Its three measurement modes, 50 mm cell holder and RS-232 computer interface make it a practical choice for laboratories performing routine visible spectrophotometric analysis. For pharmaceutical manufacturers, chemical laboratories, educational institutions, water testing facilities and industrial quality control departments, it offers a convenient solution for optical measurement and sample concentration analysis.
Standard Accessories
| Accessory | Quantity |
|---|---|
| Main Instrument | 1 Unit |
| Operation Manual | 1 No. |
| Power Cable | 1 No. |
| 10 mm Glass Cells | 4 Nos. |
| Software CD | 1 No. |
| RS-232 Cable | 1 No. |
Japsin Instrumentation – Since 1974

Reviews
There are no reviews yet.