Touch Screen Viscometer ( JIPL-V201 )

₹195,000.00

Available on back-order

Compare
SKU: JIPL-V201 Category:

Your Gateway to Precision Control. Explore Our Online Store for Cutting-edge Instrumentation Solutions. Reliable Quality, Unparalleled Performance.

Explore the JIPL Touch Screen Viscometer with a 20–2,000,000 mPa·s range, 8 RPM settings, 4 standard spindles, RTD temperature monitoring and LCD touchscreen.

Japsin Instrumentation – Since 1974

Description

Advanced Touch Screen Viscometer for Laboratory and Industrial Applications

The JIPL Touch Screen Viscometer is designed to measure the viscosity of liquids and semi-liquid materials across a wide range of laboratory and industrial applications. Viscosity is an important physical property that describes a fluid’s resistance to flow. It affects the processing, mixing, pumping, coating, dispensing and overall performance of many industrial and commercial products.

Materials such as paints, oils, adhesives, pharmaceutical formulations, cosmetics, food products, dairy products, polymer solutions and chemical mixtures require viscosity monitoring to maintain product consistency and meet quality requirements. The JIPL Touch Screen Viscometer provides a measuring range of 20 to 2,000,000 mPa·s, allowing laboratories to evaluate materials with different flow characteristics.

The instrument features a touchscreen LCD interface, stepping motor technology, multiple rotational speeds and standard interchangeable spindles. These features support convenient operation and flexible viscosity measurement.

Wide Viscosity Measurement Range

The JIPL Touch Screen Viscometer offers a measuring range of 20–2,000,000 mPa·s. This wide range supports testing of low-, medium- and high-viscosity materials, depending on the selected spindle and rotational speed.

Viscosity testing is an important part of quality assurance because changes in viscosity can affect product stability, application properties, processing behaviour and finished-product consistency. Regular measurement helps laboratories compare production batches, evaluate raw materials and monitor formulation changes.

The instrument provides direct digital readout of measurement parameters, helping operators observe the viscosity results during testing.

Touchscreen LCD Display and Direct Measurement Readout

The instrument is equipped with an LCD touchscreen that provides a convenient interface for operating the viscometer and viewing measurement information.

Its direct readout facility displays measurement parameters, while the automatic range indication helps operators identify the applicable measuring range. This reduces the need for manual range estimation and makes routine testing more convenient.

The touchscreen operating arrangement provides a modern alternative to conventional button-based viscometers and supports easier access to instrument functions.

Stepping Motor Technology for Reliable Operation

The JIPL Touch Screen Viscometer uses a stepping motor drive system. The manufacturer identifies this motor arrangement as a feature supporting accurate and reliable operation.

The motor drives the selected spindle at the chosen rotational speed. The spindle interacts with the sample, and the instrument uses the resulting measurement response to determine viscosity.

Stable rotational operation is important for obtaining consistent readings. Correct spindle selection, sample preparation, temperature control and adherence to the recommended testing procedure remain essential for reliable results.

Multiple Rotational Speeds for Flexible Testing

The instrument offers eight selectable rotational speeds:

  • 0.3 RPM
  • 0.6 RPM
  • 1.5 RPM
  • 3 RPM
  • 6 RPM
  • 12 RPM
  • 30 RPM
  • 60 RPM

The availability of multiple speeds provides flexibility when measuring materials with different flow characteristics. Lower speeds can be useful for certain high-viscosity samples, while higher speeds may be appropriate for other materials, depending on the spindle and test method.

Selecting the correct rotational speed is important because viscosity readings can depend on the measurement conditions, particularly for non-Newtonian materials. For meaningful comparisons, laboratories should maintain consistent spindle, speed, temperature and sample preparation conditions.

Four Standard Spindles with Optional Spindle

The JIPL Touch Screen Viscometer is supplied with four standard spindles: #1, #2, #3 and #4. An additional #0 spindle is available as an optional configuration according to the manufacturer’s specifications.

Different spindles are used to accommodate different sample viscosity ranges and measurement conditions. The appropriate spindle should be selected based on the sample characteristics and the manufacturer’s spindle selection guidance.

The availability of multiple spindle options makes the instrument adaptable to a variety of laboratory testing requirements.

Automatic Range and Time-Based Measurement Functions

The instrument includes an automatic range indication facility that displays the applicable measurement range. This helps operators understand the measurement capacity for the selected spindle and rotational speed.

A time function is also provided for measurement operations. This supports time-based testing procedures and helps users conduct measurements according to defined test durations.

The manufacturer additionally specifies a sound alarm when torque falls below 20%. This alert helps notify the operator when the torque reading is below the stated threshold, allowing the measurement setup to be reviewed.

Measurement Accuracy and Repeatability

The JIPL Touch Screen Viscometer has a specified measurement accuracy of ±1.0% of range and repeatability of ±0.5%.

Accuracy indicates how closely a measurement corresponds to a reference value, while repeatability describes the consistency of results when the same sample is measured under the same conditions.

These specifications make accuracy and repeatability important selection considerations for laboratories conducting routine viscosity testing. Actual results also depend on correct spindle selection, rotational speed, sample temperature, sample handling and instrument verification.

RTD Temperature Monitoring

Temperature can have a considerable effect on the viscosity of many materials. A change in sample temperature may alter its flow behaviour and influence the measurement result.

The instrument includes an RTD temperature monitoring facility and a sensor probe. This allows temperature monitoring to be considered alongside viscosity measurement, helping laboratory personnel maintain better control over test conditions.

For applications where temperature consistency is critical, users should follow the recommended sample conditioning and measurement procedures. The manufacturer does not specify the temperature measurement range or accuracy, so these details should be confirmed before purchase.

Linear Calibration and RS-232 Interface

The instrument features a linear calibration facility to support measurement calibration. It also includes an RS-232 interface for output connectivity with compatible external equipment or computer systems.

The manufacturer does not publish detailed calibration instructions, communication protocol, software compatibility or data-transfer functions. These details should be confirmed when the instrument is required for computer-based data collection or laboratory integration.

Wide Range Power Supply

The manufacturer lists a wide-range power supply feature of 100–240 V. The technical specification table separately lists AC 220 V / 50 Hz. The exact input tolerance and frequency compatibility should be confirmed with the supplier before installation.

Applications of the JIPL Touch Screen Viscometer

The instrument can be considered for viscosity testing in:

  • Paint and coating industries: Evaluation of paint, coating and related liquid formulations.
  • Pharmaceutical laboratories: Viscosity testing of suitable liquid and semi-solid formulations.
  • Food and dairy industries: Monitoring the consistency of liquid food products and dairy formulations.
  • Chemical industries: Testing oils, chemical solutions and industrial liquid mixtures.
  • Cosmetic manufacturing: Evaluation of creams, lotions and other suitable formulations.
  • Polymer and adhesive industries: Testing polymer solutions, latex materials, inks and adhesives.
  • Research and educational laboratories: Laboratory experiments, formulation development and material characterisation.

Why Choose the JIPL Touch Screen Viscometer?

The JIPL Touch Screen Viscometer combines touchscreen operation, stepping motor technology, eight selectable speeds, four standard spindles and a wide viscosity measuring range. Additional facilities such as automatic range indication, time-based measurement, low-torque sound alarm, linear calibration and RTD temperature monitoring support its use in laboratory and industrial environments.

With a measurement range of 20 to 2,000,000 mPa·s, it provides flexibility for testing different liquid and semi-liquid materials. Its digital interface and multiple measurement settings make it a suitable option for routine quality control, research and product development.

Key Features

  • Wide viscosity measuring range of 20–2,000,000 mPa·s.
  • LCD touchscreen for convenient operation.
  • Stepping motor for reliable rotational operation.
  • Eight selectable rotational speeds.
  • Four standard spindles with optional #0 spindle.
  • Direct digital readout of measurement parameters.
  • Automatic range indication.
  • Time-based measurement function.
  • Sound alarm when torque is below 20%.
  • Linear calibration facility.
  • RTD temperature monitoring with sensor probe.
  • RS-232 output interface.
  • Suitable for laboratory research and industrial quality control.

JIPL Touch Screen Viscometer – advanced digital viscosity measurement for laboratory and industrial applications.

Japsin Instrumentation – Since 1974

Additional information

Brand

"Ji" Japsin Instrumentation

Product Name

Touch Screen Viscometer

Instrument Type

Digital Rotational Viscometer

Measuring Range

20–2,000,000 mPa·s

Rotational Speeds

0.3, 0.6, 1.5, 3, 6, 12, 30 and 60 RPM

Number of Standard Spindles

4

Standard Spindles

#1, #2, #3 and #4

Optional Spindle

#0

Measurement Accuracy

±1.0% of range

Repeatability

±0.5%

Display

LCD Touchscreen

Motor Type

Stepping Motor

Measurement Readout

Direct Digital Readout

Range Indication

Automatic Range Indication

Measurement Function

Time Function

Torque Alarm

Sound Alarm Below 20% Torque

Calibration

Linear Calibration

Temperature Monitoring

RTD

Temperature Sensor Probe

Included

Output Interface

RS-232

Power Supply

AC 220 V / 50 Hz

Wide-Range Power Supply Feature

100–240 V

Dimensions (L × W × H)

400 × 350 × 360 mm

Approximate Weight

9 kg

Reviews

There are no reviews yet.

Be the first to review “Touch Screen Viscometer ( JIPL-V201 )”